• Spooled: wire wound evenly on spools, without breaks or tangles
• Fixed-length (cut-to-length according to customer length specification, shear-cut or EDM-cut)
• Coil
• Custom packaging solutions
Dimensions & Tolerances
Diameter, mm [inch]
Tolerances, mm [inch]
4.000-2.000 [0.15748-0.07874]
±0.020 [±0.00079]
2.000-1.000 [0.07874-0.03937]
±0.010 [±0.00039]
1.000-0.350 [0.03937-0.01378]
±0.010 [±0.00039]
0.350-0.260 [0.01378-0.01024]
±0.007 [±0.00028]
0.260-0.150 [0.01024-0.00591]
±0.005 [±0.00020]
0.150-0.080 [0.00591-0.00315]
±0.004 [±0.00016]
0.080-0.050 [0.00315-0.00197]
±0.003 [±0.00012]
0.050-0.025 [0.00197-0.00098]
±0.002 [±0.00008]
Mechanical Properties
Alloy Code
Straightened super-elastic (SE)
UTS σᵦ₁, MPa [ksi]
Elongation (ε%)
UPS σload, MPa [ksi]
Permanent set after 6% strain (%)
Active Af (°C)
D
≥1300 [188.5]
≥10
≥480 [69.6]
<0.5
10±7
C
≥1150 [166.8]
≥10
≥440 [63.8]
<0.5
17±7
S
≥1000 [145.0]
≥10
≥400 [58.0]
<0.5
25±5
Alloy Code
Straightened super-elastic (SE)
UTS σᵦ₁, MPa [ksi]
Elongation (ε%)
UPS σload, MPa [ksi]
Permanent set after 6% strain (%)
Active Af (°C)
D
≥1300 [188.5]
≥10
≥480 [69.6]
<0.5
10±7
C
≥1150 [166.8]
≥10
≥440 [63.8]
<0.5
17±7
S
≥1000 [145.0]
≥10
≥400 [58.0]
<0.5
25±5
* All mechanical testing conducted at 22°C±2°C per ASTM F2516-18